05/16/12 14:39:53 Cryogenic Test # 1
LN2           VAC          
North Tank 55.1 % FlowRate 0.0 GPM VG116 7.55E+2 Torr SIG 101 1.00E-11 Torr
South Tank 68.2 % Discharge Pressure 0.3 PSIG CM102 7.45E+2 Torr CCG102 1.00E-11 Torr
R1             R2          
ENGINE SPEED 0.0 RPM TE-A 296.7 K   ENGINE SPEED 0.0 RPM TE-A 0.0 K
HTR-48 POWER 0.0 % TE-B 297.3 K   HTR-48 POWER 2.0 Watts TE-B 0.0 K
PT-1 40.2 PSIG TE-C 295.0 K   PT-1 31.2 PSIG TE-C 0.0 K
PT-2 170.7 PSIG TE-D 297.7 K   PT-2 1.2 PSIG TE-D 292.0 K
V324 0.0 % TE-F 298.0 K   V324 0.0 % TE-F 0.0 K
V363 0.0 % TE-G 297.6 K   V363 0.0 % TE-G 293.0 K
He TANK 79.2 PSIG TE-H 299.7 K   PT-34 19.8 PSIG TE-H 292.0 K
LK5_5 60.863 K   3218     PT-37 24.4 PSIG TE-E 292.0 K
LK5_6 61.769 K         VT-43 316000.0 mT TE-48A 292.0 K
LK5_7 60.915 K         VT-44 356.0 mT TE-48B 292.0 K
LK5_8 62.008 K         He TANK 159.7 PSIG